30W Triple Output Switching Power Supply
|
• AC input range selectable by switch
• Protections: Short circuit/ Overload
• Cooling by free air convection
• 100% full load burn-in test
• Low cost, hogh reliability
• 1 year warranty |
case::903 129X98X38mm |
AC input voltage range ....... 85~132VAC / 170~264VAC selectable by switch
AC inrush current .................. Cold start, 18A at 115VAC, 36A at 230VAC
DC adjustment range ........... CH1: -5~+10% rated output voltage
Overload protection ............ 105%~150% fold back current limiting, auto-recovery
Setup, rise, hold up time .... 200ms, 100ms, 30ms at full load and 230VAC
Withstand voltage ................. I/P-O/P:1.5KVAC, I/P-FG:1.5KVAC, 1 minute
Working temperature ........... 0~50OC@100%, -10OC@80%, 60OC@60% load
Safety standards .................. Design refer to UL1012
EMC standards ..................... Design refer to FCC part 15 J
Connection ............................. 7P/ 9.5mm pitch terminal block
Packing ............................. 0.42kg ; 30pcs / 13.6kg / 0.86CUFT
|
|
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
PP |
|
|
50261 |
T-30A |
5V,0.5~3.0A |
±2% |
50mV |
70% |
39 |
|
|
|
|
12V,0.1~1.0A |
±2,-6% |
100mV |
|
|
|
|
|
|
-5V,0.1~0.5A |
±2,-10% |
50mV |
|
|
|
|
50262 |
T-30B |
5V,0.5~3.0A |
±2% |
50mV |
72% |
39 |
|
|
|
|
12V,0.1~1.0A |
±2,-6% |
100mV |
|
|
|
|
|
|
-12V,0.1~0.5A |
±2% |
100mV |
|
|