120W Single Output Switching Power Supply
|
• AC input range selectable by switch
• Protections: Short circuit/ Overload
• Cooling by free air convection
• 100% full load burn-in test
• Low cost, hogh reliability
• 1 year warranty |
case::902 199X98X38mm |
AC input voltage range ......... 85~132VAC / 180~264VAC selectable by switch
AC inrush current .................. Cold start, 30A at 115VAC, 60A at 230VAC
DC adjustment range ............ ±10% rated output voltage
Overload protection ............. 105%~150% shut off, AC recycle to re-start (S-100-7.5: 150%~200%)
Setup, rise, hold up time .. 200ms, 80ms, 20ms at full load and 230VAC
Withstand voltage ................. I/P-O/P:1.5KVAC, I/P-FG:1.5KVAC, 1 minute
Working temperature ............ -10~60OC (refer to output derating curve)
Safety standards ................... Design refer to UL1012
EMC standards ..................... Design refer to FCC part 15 J
Connection ............................ 7P / 9.5mm pitch terminal block
Packing .................................. 0.62kg ; 20pcs / 13.6kg / 0.8CUFT
|
Stock No. |
Model No. |
Output |
Tol. |
R&N |
Effi. |
|
50061 |
S-120-3 |
3V, 0~20A |
±2% |
100mV |
70% |
|
50062 |
S-120-5 |
5V, 0~20A |
±2% |
100mV |
78% |
|
50063 |
S-120-7.5 |
7.5V, |
0~13.6A |
±1 % |
100mV |
80% |
|
50064 |
S-120-10 |
10V, |
0~10A |
±1 % |
100mV |
80% |
|
50065 |
S-120-12 |
12V, |
0~8.5A |
±1 % |
100mV |
81% |
|
50066 |
S-120-15 |
15V, |
0~6.7A |
±1 % |
100mV |
81% |
|
50070 |
S-120-18 |
18V, |
0~5.6A |
±1 % |
100mV |
82% |
|
50067 |
S-120-24 |
24V, |
0~4.5A |
±1 % |
100mV |
84% |
|
50068 |
S-120-27 |
27V, |
0~3.7A |
±1 % |
100mV |
84% |
|
50069 |
S-120-48 |
48V, |
0~2.0A |
±1 % |
100mV |
84% |